Home - Products - Dryer

Features
- Under constant temperature if the vacuity of drum is improved, the drying speed can be shortened。
- Under constant vacuity if the heating temperature is elelvated, it can accelerate the drying speed。
- If both the vacuity and heating temperature is elevated, the drying speed can be shortened greatly。
- If a condenser is accepted, the vaporized agent in the target materials can be recollected by condenser,which is the normal drying faciility。If Model JZJS-70 liquid loop pump vacuum unit is used, the condenser can be omitted to save energy and investment。
Main uses
Suitable to the materials-drying for the lines of medicine , chemical, foodstuff, and electronics。
Technical Parameters
Modes |
YZG-600 |
YZG-1000 |
YZG-1400A |
FZG-15 |
Inner size of drying box |
Φ600×976 |
Φ1000×1527 |
Φ1400×2054 |
Φ1500×1400×1220 |
Outer size of drying box |
1135×810×1020 |
1693×1190×1500 |
2386×1675×1920 |
1513×1924×2060 |
Layer of dry rack |
4 | 6 | 8 | 8 |
Distance between layers |
81 | 102 | 102 | 122 |
Size of dry tray |
310×600×45 |
250×410×45 |
400×600×45 |
480×630×45 |
Number of dry tray |
4 | 24 | 32 | 32 |
Usepress inside of pipe |
≤0.784(8KG/CM2) |
|||
Use temperature of rack |
-35~150 |
|||
No load vacuum inside box |
1330(10mmHg) |